C4V series subplate-mounted pilot-operated check valves allow free flow from port A to B and block flow in the reverse direction.
When pilot pressure is applied to control port X, the main poppet opens, allowing flow from the lateral annular chamber (port B) to port A.
This series of pilot-operated check valves is available with 4 pilot area ratios (see ordering code).
Operating principle
In the normal state, with no pressure at control port X, the upper chamber of the main poppet connects to port B through the pilot poppet's internal chamber and lateral passages. Pressure at B acts on the upper chamber of the main poppet, pressing it against its seat and blocking flow from B to A.
When pilot pressure is applied to control port X, it moves the control pin against the hydraulic force of port B pressure on the pilot poppet and lifts the pilot poppet off its seat. This connects the main poppet's upper chamber to drain port Y1 and closes the pilot poppet's lateral passage to port B, unloading the upper chamber. Pressure from lateral port B then acts on the annular area beneath the main poppet to lift it, allowing flow from B to A.
Both the main and pilot poppets use a seated design, providing leak-free shutoff at ports A and B when closed.
Valves with position monitoring are available on request.
Technical parameters
General parameters
Nominal size NG10 NG25 NG32
Subplate mounting interface To ISO 5781
Mounting orientation Any
Ambient temperature [ºC] -20…+80
MTTFD value (mean failure-free operating time) [years] 150
Weight [kg] 2.8 4.6 6.1
Hydraulic parameters
Maximum working pressure [bar] 350
Nominal flow [l/min] 150 270 450
Operating fluid Hydraulic oil to DIN 51524…51525
Fluid viscosity, recommended/permissible range [cSt] / [mm2/s] 30…80
[cSt] / [mm2/s] 20…380
Fluid temperature, recommended/permissible range [ºC] 30…50
[ºC] -20…+70
Filtration requirements ISO 4406 (1999): 18/16/13