Introduction
The D*1FC series comprises high-performance electrohydraulic proportional directional control valves with electrical main-spool position feedback. Available sizes range from NG10 (Cetop 05) to NG32 (Cetop10), with 4 sizes in total:
D31FC – NG10 (CETOP 05)
D41FC – NG16 (CETOP 07)
D91FC – NG25 (CETOP 08)
D111FC – NG32 (CETOP 10)
The onboard digital electronic controller is housed in a rugged metal enclosure for use in harsh environments.
Nominal valve operating parameters are factory-set. The RS232 serial interface connection cable for parameter setup can be ordered as an accessory.
This series offers an innovative optional spool with integrated A-port regeneration for creating energy-saving regenerative cylinder circuits. The hybrid valve can switch between regenerative and standard circuit modes at any time.
Technical features
· Progressive flow characteristics for more sensitive flow adjustment
· Very low hysteresis
· High dynamic performance
· High flow capacity
· Center-position monitoring option
· Energy-saving integrated A-port regeneration option
· Hybrid valve switches between regenerative and standard circuit modes
General parameters
Design Pilot-operated (electrohydraulic) proportional directional control valve with onboard electronic controller
Actuator Proportional solenoid
Size NG10(CETOP 05) NG16(CETOP 07) NG25(CETOP 08) NG32(CETOP 10)
D31 D41 D91 D111
Mounting interface DIN 24340 / ISO 4401 / CETOP RP121/ NFPA
Mounting orientation Any
Ambient temperature [℃] -20….+60
MTTFD value (mean failure-free operating time) [years] 50
Weight [kg] 9 12.5 21 68.5
10, sinusoidal, 5…2000 Hz, to IEC 68-2-6
Vibration resistance [g] 30, random, 20…2000 Hz, to IEC 68-2-36
15, shock, to IEC 68-2-27
Hydraulic parameters
Maximum working pressure [bar] Internally drained pilot: ports P,A,B,X: 350; ports T,Y: 210
[bar] Externally drained pilot: ports P,A,B,T,X: 350; port Y: 210
Operating fluid Hydraulic oil to DIN 51524…51535. Specify other fluid requirements when ordering.
Fluid temperature [℃] -20….+60
Fluid viscosity, permissible range [cSt]/[mm2/s] 20….380
Recommended range [cSt]/[mm2/s] 30…80
Filtration requirements ISO 4406 (1999):18/16/13
Nominal flow at pressure drop △p=5bar per metering edge [l/min] 90/ 120 200 450 1000
Main-stage leakage at 100 bar [ml/min] 200 200 600 1000
Pilot stage [ml/min] <100
Pilot pressure [bar] 20-350
Pilot flow during step response [l/min] 2.9 4.1 6.7 15
Static/dynamic parameters
Step response time, 100% step signal 2) [ms] 35 37 66 120
Hysteresis [%] ≤ 0.1
Sensitivity [%] ≤ 0.05
Electrical parameters
Duty cycle [%] 100
Ingress protection IP65, to EN60529 (with the electrical connector correctly fitted)
Supply voltage/ripple [V,DC] 18…30, ripple <5% RMS, no surges
Current consumption, maximum [A] 2.0
Fuse [A] 2.5, medium time-delay
Input signal, code K(B), voltage [V] +10…0…-10, ripple A(P->B)
Impedance [Ohm] 100
Code E, current [mA] +20…0…-20, ripple B
Impedance [Ohm] 200